VM700T (turbo)
Video Measurement Set
Option 11
PAL Video Measurements
M
any capabilities in one instrument
Digitizing waveform monitor
Digitizing vectorscope
Picture Display
Group delay and frequency
response
Noise measurement set
Automatic measurement set
Auto mode
Unattended monitoring of PAL
video signals from studios, STLs,
Earth Stations, and transmitters
User-specified limits
Measur
e mode provides graphic
display of measurements
ICPM
K factor
Differential gain and phase
Chrominance to luminance delay
Noise spectrum
Group delay with sin x/x
Color bars
Relative to reference on most
measurements
Configurable for all standard
test signals
Award winning user interface
State-of-the-art architecture
Extremely fast update rate
Parallel and serial printer ports
Three input channels
Channel difference modes
External VGA display port
Fully documented r
emote control
operation
Har
dcopy for analysis and
documentation
Recognized with eight technical
Emmy awards and one Oscar for
outstanding contributions to the
television industry, Tektronix
world class core competencies
have enabled it to design and
deliver the most comprehensive
solutions in the industry.
The VM700T is a product of this
core competency. Recognized as
the defacto industry standard that
keeps pace with evolving cus-
tomer needs, the VM700T is a
total solution for your baseband
video and audio
1
monitoring and
measurement needs. Featur
es
such as an extremely fast and
fully automatic measurement
mode as well as full manual oper-
ation
pr
ovides the first time user
as well as the seasoned profes-
sional an unequaled value for their
test and measurement investment.
Automatic video measurement set
The VM700T Auto mode makes
standard video transmitter mea-
sur
ements quickly and automati
-
cally, including those specified
in CCIR Rep. 624-1, Rec. 567,
and Rec. 569. Both vertical inter-
val and full field measurements
can be made and compared with
user-defined limits. A dual limit
verification system is employed
to generate a caution or alarm
message when either limit is vio-
lated. Reports can be generated
and printed automatically at
operator scheduled times or trig-
gered from a conditional event.
Graphic displays of measurements
Measure mode provides virtual
real time graphic displays of
measurement results automati-
cally. Vertical interval or full
field measurements including
noise spectrum, group delay,
K-factor, dif
ferential gain and
differential phase are presented
as clever, easy to understand
interactive digital displays. Such
displays ar
e indispensable when
extremely fast measurement
update rates (up to 30 times a
second) are required to provide
instant feedback of critical
adjustments and analysis of
signal variations. User definable
limits are visually integrated into
each graphic display and can be
used to trigger a measur
ement
report or a user definable macro
function. Such a function can,
for example, dial out through a
Copyright © 1996, T
ektr
onix, Inc. All rights r
eser
ved.
1
Option 40 audio measurement package.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - PAL Video Measurements

VM700T (turbo)Video Measurement SetOption 11 PAL Video MeasurementsMany capabilities in one instrument–Digitizing waveform monitor– Digitizing vectors

Seite 2

Unified Unweighted filter response curve per CCIR Recommendation 567.0–5508MHzdBV–5–10–15–20–25–30–35–40–45–501234567Unified Luminance weighted filter

Seite 3

Measurement results are displayed in an easy-to-read format indicating the time, signal source, measurement, and whether the measured value exceeded c

Seite 4 - MEASURE MODE

Measurement methodsThe following paragraphs specifythe methods for each Option 11measurement. Where appropriate,reference is made to the relevantCCIR

Seite 5 - EASURE MODE (continued)

Other timing measurementsBar Rise Time:Measuredbetween the 10% and 90%points on the leading edge ofbar. See element B2.Amplitude and phase measurement

Seite 6

C/L Gain Inequality: Measuredas the difference between thesampled peak-to-peak ampli-tude of the 700 mV (nominal)chrominance packet (G1 or G2)and the

Seite 7

Frequency response measurementsMultiburst Flag Amplitude:Measured from the center pointof the flag top to the ensuingbottom of the flag. Resultexpress

Seite 8

Contact Tektronix:ASEAN / Australasia / Pakistan (65) 6356 3900Austria +41 52 675 3777Balkan, Israel, South Africa and other ISE Countries+41 52 675 3

Seite 9 - UTO MODE

modem to report measurementresults or control a signal router.A relative to reference modeallows normalizing to a signalsource or eliminate signal pat

Seite 10 - FREQUENCY (MHz)

Vertical interval test signals can be seen very clearly for additional analysis of the signal.These can be printed as support documentation for automa

Seite 11 - Lower Upper

Bar Line Time measurement.Chrominance to Luminance Gain and Delay measurement.MEASURE MODE1,2BAR LINE TIMEAbsolute RelativeMeasurement Range Mode Mode

Seite 12

Chrominance Non-Linearity measurement.Color Bar measurement.Luminance Level (mV )Luminance Level (mV )Chrominance Level (mV )Chrominance Level (mV )Ch

Seite 13

Frequency Response and Group Delay measurement using Sin X/X.Horizontal Timing measurement.MEASURE MODE (continued)FREQUENCY RESPONSE AND GROUP DELAYA

Seite 14

LINE FREQUENCYMeasurement Range AccuracyLine Frequency ± 3% ± 0.1%Field Frequency ± 3% ± 0.1%LUMINANCE NON-LINEARITYAbsolute RelativeMeasurement Range

Seite 15 - Information

VERTICAL BLANKINGMeasurement Range Absolute Mode AccuracyEqualizing Pulse Width 80 ns to 1 µs ± 10 nsBroad Pulse Width 80 ns to 1 µs ± 10 nsVertical B

Seite 16

AMPLITUDE AND PHASE MEASUREMENTS (continued)Measurement Range Accuracy ITS Element StandardDifferential Gain 0 to +100% ± 0.3% D2 CCIR Rec. 569(Peak a