Seitenansicht 67
Using the Menus
1740A/1750A Series Waveform/Vector Monitor User Manual
3-13
If it becomes necessary to compensate for minor shifting of
markers due to drift or external magnetic fields (particularly
if the instrument is moved after the markers are set), enter
the
CRT menu and select READOUT. Use the bezel controls to
adjust vertical position
(VPOS) and horizontal position
(HPOS) until the center of the displayed test pattern is at the
center of the graticule.
With Waveform Display
Voltage Cursors can be used to make accurate signal ampli-
tude measurements. With
VOLT selected, use the left bezel
control to position the
VOLT1 cursor at the upper excursion of
signal to be measured, and the center bezel control to posi-
tion the
VOLT2 cursor at the lower excursion. The on-screen
readout gives the voltage difference between the two levels.
When
GAIN is changed, the voltage cursors maintain their
relationship with the signal. For example, if the
VOLT2 cursor
were set to the signal sync tip in
X1 GAIN,itwouldalsobeat
sync tip in
X5 gain, X10 gain, or with VAR gain on.
Timing Cursors can be used to make accurate time measure-
ments. When
TIME is selected, position the TIME1 cursor at
the left excursion of the signal to be measured, and the
TIME2
cursor on the right. The on-screen readout gives the time
difference between the two points.
When
MAG is selected, the timing cursors maintain their rela-
tionship with the signal. For example, if the
VOLT1 cursor
were set to the rising edge of sync, it would also be set there
with
MAG selected.
Markers. When
MARK is selected, use the bezel controls to
vertically position the markers where desired with respect to
the graticule markings. These markers are designed to be
used for reference points; there is no amplitude readout. The
markers are not affected by
GAIN changes; if a marker were
set to
100 IRE in X1 GAIN, it would still be set to 100 IRE with
the
MAG on.
Seitenansicht 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 142 143

Kommentare zu diesen Handbüchern

Keine Kommentare

Foremost KNCA3021D manuals

Owner’s manuals and user’s guides for Unknown Foremost KNCA3021D.
We providing 1 pdf manuals Foremost KNCA3021D for download free by document types: Instruction Manual


Foremost KNCA3021D Instruction Manual (4 pages)


Brand: Foremost | Category: No info | Size: 3.58 MB |

 

Table of contents





More products and manuals for Unknown Foremost

Models Document Type
ZEEM3831 Instruction Manual   Foremost ZEEM3831 Instructions / Assembly, 5 pages
GAEA2418 Instruction Manual Foremost GAEA2418 Instructions / Assembly, 4 pages
CTAF1735D Instruction Manual   Foremost CTAF1735D Instructions / Assembly, 4 pages
KNCM2434 Instruction Manual   Foremost KNCM2434 Instructions / Assembly, 5 pages
LACAT2319 Instruction Manual   Foremost LACAT2319 Instructions / Assembly, 4 pages
NAWL2474 Installation Guide   Foremost NAWL2474 Installation Guide, 4 pages
NACA4821D Instruction Manual   Foremost NACA4821D Instructions / Assembly, 4 pages
CTAABG4922D Instruction Manual   Foremost CTAABG4922D Instructions / Assembly, 4 pages
AVHM2430 Installation Guide   Foremost AVHM2430 Installation Guide [en] , 4 pages
NACM3032 Instruction Manual   Foremost NACM3032 Instructions / Assembly, 6 pages
HAGOS2417 Installation Guide   Foremost HAGOS2417 Installation Guide, 4 pages
COBA2421 Instruction Manual   Foremost COBA2421 Instructions / Assembly, 4 pages
NACL2474 Instruction Manual   Foremost NACL2474 Instructions / Assembly, 8 pages