Adjustment Procedures
VITS100 NTSC VITS Inserter Instruction Manual
6–3
With the exception of the video signal connection, this step is the starting point
for any adjustment.
H Disconnect power and remove the cabinet. See the Maintenance section of
this manual for instructions.
H Connect the VITS inserter AC power cord to the variable autotransformer.
Turn the power on and set the autotransformer to 110 V.
H Connect a 75 W coaxial cable from the television test signal generator output
to the VITS inserter PROGRAM IN.
H Turn on all test equipment and allow for any required warm-up period.
H Figure 6–1 shows the location of adjustments and test points (TP) used in
this procedure.
Preliminary Setup