Tektronix MTM400 Bedienungsanleitung Seite 102

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 197
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 101
Stream View
3-54 MTM400 MPEG Transport Stream Monitor User Manual
PCR Drift Rate (PCR_DR)
This Drift Rate graph shows the rate of change of PCR Frequency Offset, which is
often very small. It is calculated using PCR Frequency Offset measurements.
Figure 3-19: Stream view - PCR graph - PCR drift rate
The Maximum PCR Drift Rate can be adjusted for all PIDs as follows:
Tests screen Î PCR Tests section Î PCR Drift Rate (PCR_DR)
parameter (right-click) Î Max PCR frequency drift rate.
For individual PIDs:
PIDs screen Î Test: select PCR Drift Rate Î individual PID parameter
(right-click) Î Max PCR frequency drift rate.
Right-click on the graph and set the limit for each PID.
Seitenansicht 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 196 197

Kommentare zu diesen Handbüchern

Keine Kommentare