AWG710&AWG710B Arbitrary Waveform Generator User Manual 2-73
2. Push the New Sequence side button. The sequence table to create a new
sequence is displayed in the screen. See Figure 2-44.
Figure 2-44: Initial sequence table
Create the Subsequence
You will create the sequence list shown in Table 2-17. This sequence is used as a
subsequence and is called from the main sequence that you create in Create the
Main Sequence on page 2-76. This sequence runs as follows:
1. Line 1: outputs the gaussian noise waveform 40,000 times and then goes to
line (2).
2. Line 2: outputs the ramp waveform 60,000 times and then goes to the next line
(3).
3. Line 3: outputs the triangle waveform 60,000 times and then goes to the next
line (4).
4. Line 4: output the sine waveform 30,000 times and then quits the subsequence
and returns to the main sequence.