Appendix A: Specifications (AWG710B)
A-10 AWG710&AWG710B Arbitrary Waveform Generator User Manual
Figure A-2: Gated Mode
1. After RUN starting, Gate signal is input
PW
min
: 1152 clocks + 10 ns
(1355 to 1563.5) clocks + 9 ns at 4 GS/s
Gate Signal
The interval of Output is equal to PW
min
The only interval of 1st Output is equal to PW
min
and the others are normal.
1-1. The interval of Gate signal is longer than PW
min
(Minimum Pulse Width) x 2
Interval = PW
min
x 2
Analog output
RUN start point
T > PW
min
x 2
Delay to Analog output
1-2. The interval of Gate signal is equal to PW
min
(Minimum Pulse Width) x 2
Gate Signal
Analog output
PW
min
PW
min
2. Before RUN starting, Gate signal is input
2-1. The interval of Gate signal is longer than PW
min
(Minimum Pulse Width) x 2
RUN start point
Gate Signal
Analog output
PW
min
Delay to Analog output
PW
min
2-2. The interval of Gate signal is equal to PW
min
(Minimum Pulse Width) x 2
As above 1-2, the interval of Analog Output is equal to PW
min
.