Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition
Sets or returns the trigger condition for FLEXRAY.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A :BUS:B<x>:FLEXray:CONDition
{SOF|FRAMETypeid|CYCLEcoun t|HEADer|DATA|IDANDDATA|EOF|ERROR}
SEARCH:SEARCH<x>:TRIGger:A :BUS:B<x>:FLEXray:CONDition?
Arguments
SOF sets the FLEXRAY trigger condition to start of frame.
FRAMETypeid sets the FLEXRAY trigger condition to a frame type id.
CYCLEcount sets the FLEXRAY trigger condition to cycle count.
HEADer sets the FLEXRAY trigger condition to header.
DATA sets the FLEXRAY trigger condition to data.
IDANDDATA sets the FLEXRAY trigger condition to ID and data.
EOF sets the FLEXRAY trigger condition to EOF.
ERROR sets the FLEXRAY trigger condition to a n e rror.
Examples
SEARCH:SEARCH1:TRIGGER:A:B US:B1:FLEXRAY:CONDITION E RROR sets
the FLEXRAY condition to ERROR
SEARCH:SEARCH1:TRIGGER:A:B US:B1:FLEXRAY:CONDITION? might
return
SEARCH:SEARCH1:TRIGGER:A:BU S:B1:FLEXRAY:CONDITION SO F
indicating the FLEXRAY condition is start of frame.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue
Sets or returns the binary data string to be used for FLEXRAY cycle count high
value.
Gr
oup
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A :BUS:B<x>:FLEXray:CYCLEcount:
HIVALue <QString>
SEARCH:SEARCH<x>:TRIGger:A :BUS:B<x>:FLEXray:CYCLEcount:
HIVALue?
MSO4000 and DPO4000 Series Programmer Manual 2-339